Peroxide-cure DOWSIL™ PSAs such as 280A, 7355, 7356, 7358 and Q2-7406 hold to 260 °C (500 °F); Q2-7566 holds to 288 °C (550 °F) and platinum-cure DOWSIL™ SD 4600 FC to 300 °C (572 °F). DOWSIL™ 7657 (platinum) has the highest probe tack in the table at 1,160 g with 1,280 g/in adhesion; DOWSIL™ 7695 reaches 1,400–1,800 g/in and DOWSIL™ 7687/7687N 1,800 g/in. Values are typical and not for specifications.
Pressure sensitive adhesives and mica binders
| Product | Cure system | Viscosity, cps | Non-volatile content, % | Adhesion, g/in | Probe tack, g | High-temperature hold/shear, °C (°F) |
|---|---|---|---|---|---|---|
| DOWSIL™ 280A Adhesive | Peroxide | 38,900 | 57 | 850 | 470 | 260 (500) |
| DOWSIL™ 7268 Adhesive | Peroxide | 53,000 | 60 | 1,240 | 600 | 240 (464) |
| DOWSIL™ 7278 Adhesive | Peroxide | 52,900 | 74 | 1,260 | 560 | 220 (428) |
| DOWSIL™ 7366 Adhesive | Peroxide | 58,100 | 57 | 900 | 400 | 220 (428) |
| DOWSIL™ 7280 Adhesive | Peroxide | 17,000 | 56 | 1439 | 217 | 220 (428) |
| DOWSIL™ Q2-7406 Adhesive | Peroxide | 31,700 | 57 | 940 | 400 | 260 (500) |
| DOWSIL™ 7388 Adhesive | Peroxide | 30,500 | 57 | 930 | 380 | 260 (500) |
| DOWSIL™ 7406-VLO Adhesive | Peroxide | 31,300 | 56 | 940 | 280 | 260 (500) |
| DOWSIL™ 7355 Adhesive | Peroxide | 20,700 | 57 | 1,200 | 430 | 260 (500) |
| DOWSIL™ 7356 Adhesive | Peroxide | 23,100 | 56 | 960 | 470 | 260 (500) |
| DOWSIL™ 7357 Adhesive | Peroxide | 28,000 | 57 | 1030 | 450 | 260 (500) |
| DOWSIL™ 7358 Adhesive | Peroxide | 20,900 | 57 | 1,050 | 490 | 260 (500) |
| DOWSIL™ Q2-7566 Adhesive | Peroxide | 33,000 | 57 | 910 | 390 | 288 (550) |
| DOWSIL™ Q2-7735 Adhesive | Peroxide | 32,800 | 57 | 1,200 | 530 | 232 (450) |
| DOWSIL™ SD 4600 FC Adhesive | Platinum | 40,000 | 60 | 810 | 320 | 300 (572) |
| DOWSIL™ 7657 Adhesive | Platinum | 22,500 | 56 | 1,280 | 1,160 | 260 (500) |
| DOWSIL™ 7667 Adhesive | Platinum | 55,000 | 70 | 400 | N/A | N/A |
| DOWSIL™ 7636 Adhesive | Platinum | 48,000 | > 99 | < 3 | N/A | N/A |
| DOWSIL™ 7666 Adhesive | Platinum | 22,500 | > 97 | < 3 | N/A | N/A |
| DOWSIL™ 7666N Adhesive | Platinum | 22,500 | > 97 | < 3 | N/A | N/A |
| DOWSIL™ 7687 Adhesive | Platinum | 45,000 | 70 | 1,800 | N/A | 200 (392) |
| DOWSIL™ 7669 Adhesive | Platinum | 48,000 | > 99 | < 3 | N/A | N/A |
| DOWSIL™ 7687N Adhesive | Platinum | 45,000 | 70 | 1,800 | N/A | 200 (392) |
| DOWSIL™ 7685 Adhesive | Platinum | 4,200 | 63 | 200-400 | 100-200 | N/A |
| DOWSIL™ 7695 Adhesive | Platinum | 14,600 | 63 | 1400-1800 | 600-800 | N/A |
| DOWSIL™ 7645 Adhesive | Platinum | 57,000 | 40 | 5 | N/A | N/A |
| DOWSIL™ 7646 Adhesive | Platinum | 56,600 | 99 | < 3 | N/A | N/A |
| DOWSIL™ 7647 Adhesive | Platinum | 7,500 | 98 | < 3 | N/A | N/A |
| DOWSIL™ 7660 Adhesive | Platinum | 46,900 | 97 | < 3 | N/A | N/A |
| DOWSIL™ 7651T Adhesive | Platinum | 27,000 | 40 | 10 | N/A | 260 (500) |
| DOWSIL™ 7652T Adhesive | Platinum | 10,000 | 40 | 200 | 30 | 260 (500) |
| DOWSIL™ 7651 Adhesive | Platinum | 27,000 | 40 | 10 | N/A | 260 (500) |
| DOWSIL™ 7652 Adhesive | Platinum | 10,000 | 40 | 200 | 30 | 260 (500) |
| DOWSIL™ 288 Mica Binder | Peroxide | 51,600 | 61 | 860 | N/A | N/A |
| DOWSIL™ 290 Mica Binder | Peroxide, silane | 38,900 | 56.5 | 860 | N/A | N/A |
| DOWSIL™ 298 Mica Binder | Peroxide, silane | 38,000 | 60 | 860 | N/A | N/A |
Solventless pressure sensitive adhesives
| Product | Cure system | Viscosity, cps | Non-volatile content, % | Adhesion, g/in | Probe tack, g | High-temperature hold/shear, °C (°F) |
|---|---|---|---|---|---|---|
| DOWSIL™ 2102 Adhesive | Platinum | 1950 | 100 | 3 | N/A | N/A |
| DOWSIL™ 2110 Adhesive | Platinum | 2000 | 100 | 50 | N/A | N/A |
| DOWSIL™ 2013 Adhesive | Platinum | 13,100 | 100 | 1,410 | 620 | 260 (500) |
| DOWSIL™ 2014 Adhesive | Platinum | 10,000 | 100 | 1,000 | 12 | 220 (428) |
| DOWSIL™ 2015 Adhesive | Platinum | 17,000 | 99 | 1,300 | 321 | 260 (500) |
Frequently asked questions
Which DOWSIL PSA has the highest high-temperature hold?
DOWSIL™ SD 4600 FC (platinum cure) is listed at 300 °C (572 °F); DOWSIL™ Q2-7566 is listed at 288 °C (550 °F).
Can these values be used for specifications?
No. Dow states the values are average quality data for comparison only and not intended for specifications; contact Dow for specification limits.
Where can I get technical support for Dow silicone PSAs in Korea?
Korea Construction Trading (KCT) supports product selection, technical documents, process conditions and troubleshooting to the best of its ability: sales@kconstrade.com, +82 10-8939-0284.
This page is based on the following document. Values are typical, not specifications; verify with the original and product data sheets before design or purchase.
Dow, “Silicone PSAs for High Performance Selection Guide”, Form No. 30-1315-01-0524 S2D, © 2024 The Dow Chemical Company (2024 최신판); Dow Corning, “Product Selection and Application Guide — Dow Corning® brand High-Performance Silicone PSAs”, Form No. 30-083B-01 (AGP7825), ©2001, 2006 Dow Corning Corporation (2006 구판). 한국어 번역·정리: 한국건설트레이딩(KCT)
Suggested citation: “Table 2: Product Specifications and Typical Performance Properties (Viscosity, Adhesion, Tack, High-Temperature Hold)”, Korea Construction Trading (KCT) Technical Information, https://kconstrade.com/en/technical/psa/product-specifications-table
More technical resources
For DOWSIL™ silicone selection, quotations and technical advice, please contact Korea Construction Trading. We do our best to support you technically, from product selection to process-condition review and troubleshooting. Technical support details →
sales@kconstrade.com010-8939-0284WhatsApp